ZIRCONIUM OXIDE O₂ PROBES
ZO₂ probes
ZO₂ probes directly and continuously measure residual oxygen in humid combustion fumes. Three mechanical versions are available to suit the application and mounting requirements. All models include control electronics, a non-isolated active or passive 4–20 mA output, range selection by jumpers, ambient-air calibration with an adjustment trimmer and a dual measuring scale. The probes can be used with methane-fired systems. For other fuels with low sulfur content, consult our technical office.
ZO₂-4I — integrated electronics
For standard conditions. This in-situ zirconium oxide probe measures residual oxygen directly and continuously in combustion fumes. Electronics integrated in the head provide a linearized 4–20 mA signal, with active or passive output selectable by jumpers.
- Sensor and heater management
- Scale range setting
- Calibration
- Output signal adjustment
ZO₂-4I/E-C060 — separate electronics
For harsh environments where high temperatures or vibration could damage on-board electronics. The separate electronics provide a linearized 4–20 mA signal, with active or passive output selectable by jumpers. A connection cable to the separate unit is supplied.
- Sensor and heater management
- Scale range setting
- Calibration
- Output signal adjustment
ZO₂-4E — separate electronics
For harsh environments where high temperatures or vibration could damage on-board electronics. The separate unit provides an active, non-isolated 4–20 mA output or a 0–10 V output selectable by DIP switch, and is supplied with a connection cable.
- Sensor and heater management
- Scale range setting
- Calibration
TECHNICAL SPECIFICATIONS
| Model | Characteristics |
|---|---|
| ZO₂-4I | In-situ zirconium oxide probe with integrated electronics. Length: 300 or 500 mm; other lengths on request. Compatible with OX instrumentation. Flue temperature up to 600 °C. Measuring range: 0.5–25% O₂. Accuracy: 0.5% f.s. Ambient-air calibration with trimmer, no cylinders. Scale: 0–20.9% or 0–25% O₂, configurable. Output: active 4–20 mA or 0–10 V. Supply: 24 VDC. |
| ZO₂-4E | In-situ zirconium oxide probe with separate electronics. Length: 300 or 500 mm; other lengths on request. Compatible with OX instrumentation. Flue temperature up to 600 °C. Measuring range: 0.5–25% O₂. Accuracy: ±1% f.s. Ambient-air calibration with trimmer, no cylinders. Scale: 0–20.9% or 0–25% O₂, configurable. Output: active or passive 4–20 mA. Supply: 24 VDC. |
| ZO₂-4I/E-C060 | Zirconium oxide extraction probe with separate electronics. Compatible with OX instrumentation. Flue temperature up to 600 °C. Measuring range: 0.5–25% O₂. Accuracy: 0.5% f.s. Ambient-air calibration with trimmer, no cylinders. Scale: 0–20.9% or 0–25% O₂, configurable. Output: active 4–20 mA or 0–10 V. Supply: 24 VDC. |
DOCUMENTS AND MANUALS
-
User manual
-
User manual
-
Technical bulletins
-
CE declarations